TP31 (OST POWER 31) three insingle out UPS Series
TP31 Series Products
TP31 series of three single out OST UPS is designed for data center technology companies, network computer room, smart sophisticated equipment designed for high performance sine wave UPS, its high reliability for the financial, telecommunications, insurance, transport, taxation, military , securities, energy, education, government, manufacturing, business and other industries to provide a critical power protection.
TP31 Series is a true double-conversion on-line UPS, uses advanced IGBT power devices, superior performance SPWM inverter and intelligent multi-mode technology, advanced battery management technology, as well as a wealth of power management software, has a good Cost-effective and user base, and to provide users with an isolation transformer, external chargers and adapters, and other optional SNMP.
TP31 Series technical characteristics
China Power Grid environment for the design, improve system availability
◆three single out 380V/220V, suitable for Chinese power grid;
◆Wide AC input voltage range, reducing the frequency of use of the battery, effectively extending the battery life;
◆Wide input frequency range, to ensure access to a variety of fuel generators can be stable;
◆super phase the ability to work to ensure that the system is stable power supply in extreme situations.
Highly reliable and stable operation of the design concept, protect network systems
◆Pure online double conversion topology architecture designed to provide the best power quality;
◆using SPWM pulse width modulation, IGBT power modules and output isolation transformer, ensure that the UPS output without interference from power fluctuations and noise;
◆the use of advanced technology and electronic lock-synchronous static bypass switch, output zero transfer time to meet the high standards of precision equipment for power supply requirements to ensure the continuity of load power;
◆Based on advanced microprocessor (MCU) control technology to enhance the availability and reliability of the system.
ABM intelligent battery management technology to effectively delay the battery life
◆using ABM intelligent battery management technology to maximize the activation of the battery, which greatly extend battery life, improve the quality of rechargeable batteries, shorten the charging time, and have a battery failure early warning capabilities;
◆can flow both parallel self-power charger, sharing imbalance ≤3%, effectively shortening the charging time, the maximum configuration of the system to meet the requirements.
Goodwill of the man-machine interface and network management capabilities, makes machine communication distance
◆have a variety of sound and light warning function, concise;
◆Large-screen LCD Chinese LCD interface to provide accurate UPS operating parameters and working conditions;
◆through RS232 interface, with smart UPS monitoring software can be used with a PC for instant messaging, various parameters and status of the UPS system at a glance display on the PC communication interface, by setting, the computer can perform a variety of functions for UPS systems direct control;
◆DB9 with RS485 interface and optional dry contact interface functions;
◆The external SNMP adapter, the system has a direct Internet access, providing instant messages UPS data and power through a variety of network management platform for communication, management, system instantly become a network.
TP31 Series Applications
Small and medium-scale network systems / data room, business services group, industrial process control applications, small and medium scale office automation, computer equipment, precision instruments, medical equipment and so on.
TP31 Series Model name defined
TP31 ***
TP31: said three single out series
*: Indicates the UPS capacity, the unit is Kva
*: Indicates whether the built-in battery, with the S suffix indicates built-in battery, the series UPS only 6Kva the following capacity (including 6Kva) may be within
Set the battery.
Such as: TP3120 is expressed as three single out 20Kva time-lapse host, TP3106S represented as three single out the built-in battery 6Kva standard machine.
TP31 Series Technical Specifications Table
Model |
TP3106 |
TP3110 |
TP3112 |
TP3115 |
TP3120 |
TP3125 |
TP3130 |
|
Capacity |
6KVA |
10KVA |
12KVA |
15KVA |
20KVA |
25KVA |
30KVA |
|
AC input | ||||||||
Voltage |
Three-phase input 380VAC ±20% |
|||||||
Frequency |
50(60) Hz ±5% |
|||||||
Maximum current |
10A |
16A |
20A |
24A |
32A |
42A |
48A |
|
AC output | ||||||||
Voltage |
Single-phase 220VAC |
|||||||
Frequency |
50(60) Hz |
|||||||
Voltage stability |
±1% |
|||||||
Frequency Stability |
±0.5% (when mains power failure) |
|||||||
Waveform |
SPWM sine wave |
|||||||
Power factor |
0.8 (lagging) |
|||||||
Distortion |
<3% (linear load) |
|||||||
Transient response |
Voltage variation ≤4% (100% load into or cut out) |
|||||||
Output current crest factor |
3:1 (Max.) |
|||||||
Battery | ||||||||
Voltage |
192VDC |
|||||||
Type |
Maintenance-free lead-acid batteries |
|||||||
Charging time |
Completed 90% capacity within 8-10 hours |
|||||||
Warning devices | ||||||||
Mains power |
The buzzer beeps once every 4 seconds |
|||||||
Mains abnormal |
The buzzer beeps once every four seconds, mains mode indicator flashes |
|||||||
The battery will run out |
The buzzer beeps once every second, the battery mode indicator flashes, battery low voltage lights |
|||||||
Overload |
Overload indicator light, buzzer sounding |
|||||||
UPS abnormal |
Malfunction indicator light, buzzer sounding |
|||||||
Internal protection | ||||||||
Battery |
Low battery automatic shutdown, automatic restart utility power is restored, miniature circuit breaker protection |
|||||||
Overload |
Go to bypass automatic overload (120-150%) after 60 seconds, after the resumption of normal load |
|||||||
Over Temperature |
UPS internal temperature> 85 ℃automatically go to bypass |
|||||||
Output short circuit |
Limiting, automatic shutdown, mini circuit breaker protection |
|||||||
UPS abnormal |
Automatically go to bypass the mains load |
|||||||
Clutter filter |
10~100KHz at 40dB; 100KHz~100MHz at 70dB |
|||||||
Control Panel | ||||||||
LCD Display |
UPS operating status display, input, output voltage; input and output frequency; battery voltage; Output Power (%); inverter temperature |
|||||||
Low battery indicator |
When the battery voltage is low light |
|||||||
Overload indicator |
Overload light |
|||||||
Fault indicator |
Failure light |
|||||||
UPS status indicators |
AC mode; battery mode; inverter power supply; bypass supply; UPS abnormal |
|||||||
Safety standards | ||||||||
Safety |
GB4943 |
|||||||
EMI |
IEC62040-2,GB7260.2 |
|||||||
EMS |
IEC61000-4-2~5,GB/T 17626.2~5 |
|||||||
Environment | ||||||||
Temperature |
0~40℃ |
|||||||
Humidity |
20 ~ 90% non-condensing |
|||||||
Elevation |
Less than 1000m (above sea level for each additional 500m, UPS output derating 5%) |
|||||||
Noise |
<58dB (at 1 m from the box) |
|||||||
Appearance | ||||||||
Input and output wiring |
Terminal Blocks |
|||||||
Weight (without battery) |
85Kg |
130Kg |
140Kg |
220Kg |
260Kg |
320Kg |
350Kg |
|
DimensionsW × D × H (mm) |
250×580×700 |
310×590×850 |
410×680×1020 |
|||||
Other | ||||||||
Overall efficiency |
>87% |
|||||||
Mains power conversion time |
0ms |
|||||||
Inverter / bypass transfer time |
≤1ms |
|||||||
Communication Interface |
RS232 interface for direct external SNMP card; RS485, DB9 dry Node Optional |